Glass unit replacement
We replace a cracked or fogging glass unit quickly and precisely, keeping the original frame and profile. We replace glass and glass units for all types of PVC (plastic), wooden and aluminium windows.
Order this serviceWhat's included
- Removing the damaged glass unit
- Precise measurement and ordering
- Installing the new glass unit
- 24-month warranty
- Seal check
Price list by material
Prices vary by window material. Choose your type:
| Service | Price |
|---|---|
| Standard glass unit (up to 1 m²) | €80–120 |
| Large glass unit (over 1 m²) | from €120 |
| Balcony door glass unit | €140–250 |
| Triple-chamber glass unit | by quote |
| Tempered glass | +30% |
* PVC frames are the most common option. Installation is done on site without replacing the frame.
| Service | Price |
|---|---|
| Standard glass unit (up to 1 m²) | €100–150 |
| Large glass unit (over 1 m²) | from €150 |
| Balcony door glass unit | €140–200 |
| Special glass with UV filter | +40% |
* Wooden frames — precise measurement is essential. Replacing the seal around the glass is often also needed.
| Service | Price |
|---|---|
| Standard glass unit (up to 1 m²) | €130–200 |
| Large glass unit (over 1 m²) | from €200 |
| Façade and system structures | by quote |
| Commercial premises | by quote |
* Aluminium systems require special tools. The price depends on the profile manufacturer.
| Service | Price |
|---|---|
| Skylight glass unit (Velux, Fakro, Roto) | €140–220 |
| Large skylight glass unit | by quote |
| Installation above 2.5 m from the floor | by quote |
| Glass with UV protection | +25% |
* Skylights (Velux, Fakro, Roto, etc.) require a special glass unit with UV protection and condensation resistance.
| Service | Price |
|---|---|
| Façade glazing element (up to 2 m²) | by quote |
| Structural façade elements | by quote |
| Work at height (above the 3rd floor) | by quote |
* Façade glazing requires special equipment. The price depends on height, access and the system manufacturer.
Glass unit types and insulation
Below are the most common glass unit types with their heat transfer coefficient Ug (W/m²K). The lower the Ug, the better the insulation and the lower the heating bills.
| No. | Structure | Ug (W/m²K) |
|---|---|---|
| 1 | 4cf / 16 / 4cf | 2.6 |
| 2 | 6cf / 16 / 6cf | 2.6 |
| 3 | 6cf / 16 / 4cf | 2.6 |
| 4 | 4cf / 12 / 4cf / 12 / 4cf | 1.8 |
| 5 | 33.1 Lam / 16 / 4cf | 2.6 |
| 6 | 33.1 Lam / 16 / 33.1 Lam | 2.6 |
| 7 | 4cf / 16 / 4 Low-E1.1 | 1.1 |
| 8 | 6cf / 16 / 4 Low-E1.1 | 1.1 |
| 9 | 33.1 Lam / 16 / 4 Low-E1.1 | 1.0 |
| 10 | 4cf / 12 / 4cf / 12 / 4 Low-E1.1 | 0.7 |
| 11 | 33.1 Lam / 16 / 6 Low-E1.1 | 1.1 |
| 12 | 4 mat / 16 / 4 Low-E1.1 | 1.1 |
| 13 | 4 Antisan / 12 / 4cf / 12 / 4 Low-E1.1 | 1.0 |
| 14 | 4 Antisan / 12 / 4 Low-E1.1 | 1.1 |
Improve insulation with a Thermo spacer
Besides the type of glass unit, the spacer bar between the panes makes a significant contribution to insulation. By replacing the standard aluminium spacer with a Thermo spacer (made of plastic or composite material), you can significantly improve the window’s overall insulation.
What it gives in practice:
- improving the window’s overall heat loss (U-value) by about 5–18%
- improving the window’s heat transfer coefficient by about 0.15–0.2 W/m²K
- reducing heat loss through the glass unit edge by up to 30% compared with an aluminium spacer
- reducing condensation at the glass edges by up to 70%
- the inner glass edge becomes warmer by 4–9°C in winter
A Thermo spacer is a simple, effective way to improve the glass unit’s performance — it is fitted when the new glass unit is made, with no extra installation cost.
Frequently asked questions
Why does fogging appear between the panes?+
How long does glass unit replacement take?+
Can just the glass be replaced, keeping the old frame?+
What is the difference between a single- and double-chamber glass unit?+
What does Low-E glass mean?+
Can a glass unit be replaced in winter?+
Specialist advice
Find out when it’s time to replace a glass unit
How to check in 10 seconds whether a glass unit is damaged
Carefully look at the glass from inside against the light. If you see fogging, a grey film or condensation between the panes (not on the inner or outer surface), the glass unit’s seal has failed.